Pneumatic angle seat valve

Sanitary clamp pneumatic angle seat valve

Click the image for a larger viewSanitary clamp pneumatic angle seat valve
  • Body materialSS304,SS316,SS316L
    Core materialSS304,SS316,SS316L
    Connection typeClamp
    Nominal pressurePN16KG
    Structure typeY-type
    Control typeSingle acting, double acting
    Pneumatic actuatorPolyamide PA, stainless steel
    Pneumatic accessorySolenoid valve, limit switch box, positioner, handle wheel, etc
Product parametersSize chartworking principle

Standard technical parameters


Body material:304316316L

Spool material: 304316316L

Seat material: PTFEF46

Nominal size: DN15-DN80mm

Applicable temperature: PTFE:-30180

F46: -30220

Actuator must be used stainless steel material

Ambient temp.:-3080

Nominal pressure: 1.6Mpa

Connection type: Clamp, welding

Design standard: GB, ANSI, DIN, ISO

Control type: Single acting, air to open type

Single acting, air to close type

Double acting

Actuator material: Polyamide PA, stainless steel

Optional accessory: Solenoid valve, limit switch box, positioner, etc.




Size

Inch

Inner diameter

Kv Value

The max. pressure differential

Air supply

The cylinder bore

Flow direction



DN10

3/8’

10

3.7

0-16bar

4-7bar

50

Steam, gas,

Flow above seat


DN15

1/2’

15

4.2

50


DN20

3/4’

20

8.0

50


DN25

1’

25

19.0

63


DN32

1-1/4’

32

27.5

63


DN40

1-1/2’

40

42.0

63

Liquids, gas

Water hammer-free

Flow below seat


DN50

2’

50

55.0

80


DN65

2-1/2’

65

90

100


DN80

3

80


100


DN100

4

100


125


Clamp pneumatic angle seat valve


outline size drawing:



Type specification table:


Size

Inch

Clamp connection

L

L1

D

H

L2

DN10

3/8’






DN15

1/2’

180

120

50.5

137

64

DN20

3/4’

185

140

50.5

145

64

DN25

1’

210

160

50.5

173

80

DN32

1-1/4’

240

176

50.5

210

80

DN40

1-1/2’

250

190

50.5

260

80

DN50

2’

330

210

64

301

100

DN65

2-1/2

380

225

91

360

126

DN80

3

405

255

106

385

126
























Control mode:

According to the site condition has the following three kinds of control mode, the reasonable selection of the control method can make your valves service life more longer, more convenient operation, cost savings.

Normally open type user: Suitable for pneumatic valve in the working time longer occasion. When the valve is normally open spring does not load external gas source thrust, then the valve fatigue to a minimum. Because it is by the air pressure to close valve, so need filed air pressure stability, air supply reliable.

Normally closed type user: Suitable for pneumatic valve is in the closed time working longer occasion. For depends on the spring to close, when air pressure to drive the piston push spring, valve open. So for the normally closed user this valve service life more long, gas more economical. At the same time when the air supply fails, the valve is in the closed state, this control state is the most widely used.

Double acting type user: Double acting type refers to the two chambers can be input compressed air separately, realize the two-way movement of the cylinder, no spring in the cylinder, the valve opening and closing rapidly, and can be used for large stroke valve, because it is by air pressure to close valve, so need the field gas source stability, air supply reliable.












NO.

1

2

3

4

Name

Positioner

Limit switch

Switch

prompt feedback

Solenoid valve

Input signal

4-20Ma, 0-5v, 1-10v



AC220V; DC24V

Output signal

Optional: 4-20mA, 0-5v, 1-10v

Built-in

two passive contact switch

Built-in float switch


Function

The remote flow control, temperature control

Feedback

valve open and closed postion

Site operation beservation

Solenoid valve losing and get electricity, control the air reversing, realize the pneumatic valve switch.

Recommended products